DONGGUAN YUYANG INSTRUMENT CO., LTD

Manufacturer from China
Verified Supplier
8 Years
Home / Products / Electrical Test Set /

Ct Current Transformer Electrical Test Set , Touch Screen Ct Testing Equipment

Contact Now
DONGGUAN YUYANG INSTRUMENT CO., LTD
Visit Website
City:dongguan
Province/State:guangdong
Country/Region:china
Contact Person:MrAnson
Contact Now

Ct Current Transformer Electrical Test Set , Touch Screen Ct Testing Equipment

Ask Latest Price
Video Channel
Brand Name :YUYANG
Model Number :CPT-3
Certification :CE
Place of Origin :China
MOQ :1 Set
Price :Negotiable
Supply Ability :100 sets per month
Delivery Time :15 days
Packaging Details :Plywood case
Keyword :CT Current Transformer Tester
Test standard :IEC60044-1, IEC60044-6, IEC60044-2, IEC60044-5, C57.13
Power supply :AC220V±10%, 50/60Hz±10%
Display :LCD touch screen
Memory capacity :>1000 groups
Software :English
Test object :ct current transformer
Warranty :1 Year
Size :485mm×356mm×183mm
Weight :15kg
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

CT Tester CT Analyzer CT Testing Equipment Electrical CT Test Set

Tester for current transformer:

1.Excitation curve and parameters test
2.Turns ratio test
3. Ratio and phase error test
4. Polarity mark check
5. Coil resistance measurement
6. Secondary loop burden measurement
7. Error line curve test for protection CT
8. Transient CT parameters test
9. CT nameplate guess
10.Saturation hysteresis loop curve measurement

Applications of CT Current Transformer Tester:

1 CT nameplate check
2 CT parameters check in work burden
3 CT transient parameters analysis

4 CT ratio and phase error calibration

Specifications:

Item Name CT Current Transformer Tester
Test standards IEC60044-1, IEC60044-6, IEC60044-2, IEC60044-5, C57.13
Power supply AC220V±10%, 50/60Hz±10%
Voltage output 0.1~125V (AC)
Current output 0.001~5A(RMS)
Power output 300VA
Max. knee voltage measurement 45KV
Current measurement
Range 0~10A (automatically change range in 0.1/0.4/2/10A)
Error <±0.1%+0.01%FS

Voltage measurement Range 0~200V (automatically change range in 1V/10V/70V/200V)
Error < ±0.1%+0.01%FS
Turns ratio measurement Range 1~35000
1~2000, error<0.05%
2000~5000,error<0.1%
5000~35000,error<0.2%
Phase measurement error ±2min
resolution 0.01min
Coil resistance measurement Range 0~80Ω (automatically change range in 2ohm/20ohm/80ohm)
Error < 0.2%RDG+0.02%FS
Maximum resolution : 0.1mΩ
Temperature measurement -50~100 Celsius degree; error<3 Celsius degree
CT Secondary burden Range 0~160ohm (automatically change range in 2ohm/20ohm/80ohm/160ohm)
Error <0.2%RDG+0.02%FS
Maximum resolution : 0.001ohm
Memory capacity >1000 groups test results
Working condition temperature -10℃~50℃; moist ≤90%

Ct Current Transformer Electrical Test Set , Touch Screen Ct Testing Equipment