White Light Smoke Density Tester ISO 9705 EN 13823 With Light Measuring System

Ask Latest Price
Video Channel
Brand Name :YUYANG
Model Number :YY714
Certification :DIN 50055, ISO 9705, EN 13823, IEC 60332 Part 3, EN ISO 9239-1
Place of Origin :China
MOQ :1 set
Price :Negotiation
Payment Terms :T/T, L/C, Western Union
Supply Ability :5 sets per quarter
Delivery Time :15 work days
Packaging Details :Plywood Box
Product Name :Smoke Density Tester
Usage :White Light Smoke Test
Material :Stainless Steel
Power :220V 50HZ 16A
Weight :20kg
Dimension :85(W)*55(D) *45(H)
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

White Light Smoke Measurement System Used for ISO 9705, EN 13823, EN ISO 9239-1

Introduction:

‘Smoke Density Photometric System’ (DIN 50055) is designed to be used in conjunction with equipment that measures smoke from burning materials. The unit can be fitted to several instruments such as the Room Corner Test, (ISO 9705), Single Burning Item (SBI), (EN 13823), Heat Release Apparatus for IEC 60332 Part 3 (as developed in the FIPEC project), Steiner Tunnel or Flooring Radiant Panel (EN ISO 9239-1) etc.

The apparatus consists of:

1. Light Source

2. Light Measuring System

3. Control Unit

Standards:

DIN 50055, ISO 9705, EN 13823, IEC 60332 Part 3, EN ISO 9239-1

Detailed Parameter:

The Light Source is a gas filled tungsten filament lamp. Power for the lamp is provided by a regulated power supply housed in the Control Unit.

1. The Light-Measuring Device consists of: -

2. Achromatic system of lenses

3. Silicon photo-electric cell

4. High gain low noise amplifier

These components are housed in an assembly with a collimating lens.

The signal from the Light-Measuring Device is taken to the Control Unit, which is capable of continuously measuring relative light intensity against time as percentage transmission over the ranges to be studied. The system has a linear response with respect to transmittance and an accuracy of better than ±1.5% of the maximum reading. The Control Unit also regulates the damping of the amplifier so that the response times required to achieve 95% accuracy (T95) correspond to the specifications given in the standard.

An analogue output on the control unit of 0–1V = 100% transmission is available to be taken to a data acquisition unit. A Windows based software package is also available to enable simple data acquisition, analysis and storage via a data logger. All parameters are displayed. The versatile data logger may be used in other applications and is supplied with software that allows the data stored in the logger to be downloaded to a PC for further analysis.